PHAENYXCivil preparedness EN

North Macedonia · Shelter standards

What are the technical standards for shelters in North Macedonia?

North Macedonia's 2011 rulebook sets public shelters at 100 kPa, for a 7-day stay of up to 300 people, with 3 litres of water per person a day.

Updated 2026-11-16· 3 official sources· Читајте на македонски

Short answer. The Rulebook on technical norms for building public shelters, issued by the Protection and Rescue Directorate and published in the Official Gazette no. 48 of 11 April 2011, defines a basic-protection shelter: 100 kPa of overpressure resistance and rooms fitted for an uninterrupted seven-day stay of up to 300 people 1. Water reserves are 3 litres per person per day, for at least seven days 1.

Which text sets the standard?

The Правилник за техничките нормативи за изградба на јавни засолништа (Rulebook on technical norms for building public shelters), adopted by the director of the Protection and Rescue Directorate under article 63 of the Law on Protection and Rescue 13. The law says public shelters are built for basic protection in line with these norms 3.

What does a basic-protection shelter have to withstand?

A shelter is a building, or part of one, for the basic protection of people, property and cultural heritage in natural disasters and other accidents, in peace, emergency and war 1. It must have closed, linked rooms that protect against the mechanical, thermal, radiation and chemical effects of weapons, an entrance and an emergency exit resistant to blast, and built-in equipment to close openings and meet the basic needs of the occupants 1.

Requirement Basic-protection shelter 1
Overpressure resistance 100 kPa
Stay 7 days, uninterrupted
Capacity Up to 300 people
Drinking and hygiene water 3 litres per person per day, at least 7 days in total

The rulebook also sets the number and size of entrances and the width of entrance corridors by number of occupants, with smaller widths allowed when existing rooms are reconstructed as shelters 1.

Are there lighter categories?

Yes. The 2010 government decree on public shelters distinguishes 2:

  • shelters: closed, hermetically sealed rooms with air-filtering installations;
  • refuges (засолни), open or hermetic, without air filtering, where people use personal radiological, chemical and biological protection; refuges against blast, fragments and collapsing buildings resist 25-50 kPa;
  • refuges with a reinforced slab: a massive double-reinforced concrete slab 25 cm thick that protects against collapse.

Who checks shelters?

Ventilation installations are tested by registered firms 2. Shelters managed by the Directorate get quarterly, six-monthly and annual inspections, and every shelter has a maintenance book recording technical checks and repairs 2. Servicing and certification are done only by firms with licensed staff 3.

Does the standard apply to my house?

The rulebook covers public shelters. No law requires a shelter in private buildings; see Build a shelter in North Macedonia. Nothing on this page is a design instruction: shelter structures must be designed by a licensed engineer. See Safe-room standards, Shelter ventilation and NBC filtration.

Frequently asked questions

How long is a North Macedonian shelter designed for?

Seven days of uninterrupted stay 1.

How much water must a shelter store?

3 litres per person per day of drinking and hygiene water, at least seven days' worth 1.

What overpressure must it resist?

100 kPa for a basic-protection shelter; 25-50 kPa for lighter refuges 12.

Preparedness index: North Macedonia ranks 56th of 83, 46/100 · full ranking

Sources · 3

  1. Protection and Rescue Directorate (DZS), Законска регулатива · Правилник за техничките нормативи за изградба на јавни засолништа (Official Gazette 48/2011) checked 2026-11-16
  2. Government of the Republic of Macedonia — copy on dzs.gov.mk, Законска регулатива · Уредба за начинот на изградба на јавните засолништа и одржувањето и користењето на веќе изградените засолништа и другите заштитни објекти и определување на потребниот број на засолнишни места (Official Gazette 153/2010) checked 2026-11-16
  3. Protection and Rescue Directorate (DZS), Законска регулатива · Закон за заштита и спасување — редакциски пречистен текст (Law on Protection and Rescue, consolidated text, to Official Gazette 251/21) checked 2026-11-16

Keep reading: Shelter standards

Live in 83 countries

Know before disaster strikes.

Phaenyx Alert sends 19 types of alerts for the places you choose: official government warnings and scientific detections, each with its source. Free, no account, no App Store.